Site Technical Documentation –myC-1
Ref. SCT U38 SSC DTS 0016 - Index A – May 6, 2004 Page 5-1
Test description
This test tests myC-1 phones during a call.
Required tools
A Wavetek
A RF coupler or a myC-1 interface.
A myC-1 calibration tool
Test procedure
1. Position the calibration tool first on the RF coupler to calibrate it
2. Position the myC-1 module on the RF coupler
3. Switch the Wavetek on and press on "AUTOTEST".
4. Choose the corresponding program using the "UP" and "DOWN" arrows.
Mobile :myC-1
Frequency range : GSM, DCS or GSM/DCS,
Coupling type : CABLE.
5. Press on "ENTER" and wait until the end of the calibration.
6. Follow the instructions shown on the Wavetek.